Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-04.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Quality Control Program and Its Results of Korean Society for Cytopathologists.
Skip Navigation
Skip to contents

J Pathol Transl Med : Journal of Pathology and Translational Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > J Pathol Transl Med > Volume 19(2); 2008 > Article
Review Quality Control Program and Its Results of Korean Society for Cytopathologists.
Hye Kyung Lee, Sung Nam Kim, Shin Kwang Khang, Chang Suk Kang, Hye Kyoung Yoon
Journal of Pathology and Translational Medicine 2008;19(2):65-71
DOI: https://doi.org/10.3338/kjc.2008.19.2.65
1Department of Pathology, Eulji University Hospital, Korea.
2Department of Pathology, P&B Pathology Clinic, Korea.
3Department of Pathology, Seoul Asan Medical Center, Korea.
4Department of Pathology, Yeouido St Mary Hospital, Korea.
5Department of Pathology, Pusan Paik Hospital, Korea. pathyoon@inje.ac.kr
  • 2,346 Views
  • 21 Download
  • 9 Crossref
  • 0 Scopus

In Korea, the quality control(QC) program forcytopathology was introduced in 1995. The program consists of a checklist for the cytolopathology departments, analysis data on all the participating institutions' QC data, including the annual data on cytologic examinations, the distribution of the gynecological cytologic diagnoses, as based on The Bethesda System 2001, and the data on cytologic-histolgical correlation of the gynecological field, and an evaluation for diagnostic accuracy. The diagnostic accuracy program has been performed 3 times per year with using gynecological, body fluid and fine needle aspiration cytologic slides. We report here on the institutional QC data and the evaluation for diagnostic accuracy since 2004, and also on the new strategy for quality control and assurance in the cytologic field. The diagnostic accuracy results of both the participating institutions and the QC committee were as follows; Category 0 and A: about 94%, Category B: 4~5%, Category C: less than 2%. As a whole, the cytologic daignostic accuracy is relatively satisfactory. In 2008, on site evaluation for pathology and cytology laboratories, as based on the "Quality Assurance Program for Pathology Services" is now going on, and a new method using virtual slides or image files for determining the diagnostic accuracy will be performed in November 2008.


J Pathol Transl Med : Journal of Pathology and Translational Medicine